Learn PLC Under 1 Hours | Siemens S7 1200

Main summary

Key takeaways

Educational

Main ideas / lessons conveyed

1) What an S7-1200 PLC is made of (hardware architecture)

The video focuses on Siemens S7-1200 (S7-1200) PLC hardware, especially:

  • CPU (example shown: CPU 1214C), including built-in:
    • Digital inputs (DI)
    • Digital outputs (DO)
  • Extension IO modules (example mentioned: SM1223 / “SM1 22 3” / similar digital in/out modules)
    • The type/selection of IO modules depends on how many field inputs/outputs are needed.
  • Later mention that there are also analog input/output modules, though they’re not covered fully in the opening.

2) Power supply and wiring fundamentals for S7-1200

The PLC system uses a power supply whose purpose is to:

  • Convert AC to 24 V DC
  • Provide 24 V DC power to the CPU and IO modules

Key wiring steps emphasized:

  • On the AC side:
    • Connect Neutral (N) to neutral
    • Connect Live (L) to live
  • Safety instruction: make connections only when the power supply is cut off
  • On the DC side:
    • Connect 24 V positive to L+ (L positive) (positive terminal on the CPU)
    • Connect 24 V negative to M (negative terminal)
  • After powering:
    • The CPU enters RUNNING mode
    • Associated modules show powered/ready indicators

3) Rack / rail mounting and how CPU shares power/data with IO modules

The video describes mounting on a DIN rail / mounting rail (“DNR / metal rail”).

  • CPU mounting:
    • Open the mechanical latch
    • Insert/tighten the CPU into the rail
  • Key concept (“trick” shown):
    • The CPU provides data and power sharing to attached IO modules via a dedicated port/backplane slot connection on the rail/rack.
  • IO expansion:
    • IO modules are inserted “in line” and connect through the same rail interface.

4) Real plant PLC panel example (field-to-PLC concept)

The presenter shows a real PLC panel / rail feed setup in an actual plant.

  • Field level:
    • Transmitters/sensing elements (pressure/flow related) provide signals via wiring
  • Signal termination and interface:
    • Field signals terminate at terminal blocks (TBs)
    • TB outputs go to PLC IO cards/modules
  • Control room/panel components (conceptual examples):
    • Network switch connections to devices like HMI
    • Mentioned safety-related elements (e.g., safety relay, door interlocks, emergency stop)
    • Panel power supply and circuit breakers
      • including 220 VAC passing through breakers before powering the supply
  • Simplified wiring-drawing overview:
    • Inputs coming into the PLC (often via 24 V positive and M/negative reference)
    • Outputs going from PLC to actuators/final control elements

5) Programming S7-1200: connecting a laptop and building the first project

Physical connection / cable and protocol

  • Programming uses an Ethernet cable
  • Laptop connects to the PLC Ethernet port
  • (Older Siemens programming cable types for S7-300/S7-400 are mentioned in contrast.)

Software workflow (TIA Portal)

  • Open TIA Portal
  • Create a new project
  • Add a device:
    • Select the CPU type available for S7-1200 / 1500
    • Specifically select CPU 1214C
    • Verify it matches the hardware order number

Hardware configuration (IO modules)

  • In TIA Portal, add/confirm IO modules to match the real hardware (digital IO modules are referenced as examples)

IP / network setup (important)

  • Ensure the laptop and PLC are on the same subnet
  • Example:
    • PLC IP must be known/set
    • Laptop IP might be set to 192.168.0.x
    • Subnet mask: default
    • Do not set the laptop to the same IP as the PLC
  • Instruction:
    • If the laptop is not on the correct network/subnet, you cannot communicate with the PLC

First logic example (simple start/stop-like “light/fan”)

  • Use:
    • One digital input and one digital output
  • Addressing:
    • Inputs: e.g., I0.0 (byte then bit; each byte has 8 bits)
    • Outputs: e.g., Q0.0
  • Create ladder/contact-style logic:
    • I0.0 drives Q0.0
    • Named tags like “input one” / “output one” are suggested for clarity

Download & test

  • Use Download
  • Select the correct interface (video mentions “interface profet”)
  • Test via online/simulation view:
    • Switching the selector/input on/off should toggle the output/light accordingly

Methodology / instruction-style content (detailed bullet points)

A) Hardware wiring: power supply to PLC (S7-1200)

  • Safety first
    • Ensure the power supply is cut off before wiring.
  • AC side
    • Connect Neutral (N) to neutral
    • Connect Live (L) to live
  • Power supply role
    • Convert AC → 24 V DC
  • DC side to CPU/modules
    • Connect 24 V positive to terminal labeled L+
    • Connect 24 V negative to terminal labeled M
  • Verification after power on
    • Confirm CPU is in RUNNING mode
    • Confirm modules indicate power/ready

B) Rack/rail installation (mounting and module expansion)

  • Mount CPU on DIN rail
    • Open latch → insert CPU → close latch
  • Connect IO modules in-line
    • Attach IO modules to the rail/backplane slot interface
    • CPU supplies data + power through the rail connection

C) Plant wiring concept (field → TB → PLC inputs)

  • Field produces signals via instruments/sensors/transmitters
  • Signals terminate at terminal blocks (TBs)
  • TB outputs wire into the appropriate PLC input modules/IO cards
  • Panel includes networking/control for devices like the HMI

D) Programming workflow in TIA Portal (S7-1200 + Ethernet)

  • Physical connection
    • Connect an Ethernet cable from laptop to PLC Ethernet port
  • Software workflow
    • Open TIA Portal
    • Create new project
    • Add device/CPU:
      • Select CPU 1214C
      • Verify correct hardware type/order number
    • Confirm/add IO modules under device configuration
  • Network setup
    • Find PLC IP (must be known)
    • Set laptop IP to the same subnet
      • Example: 192.168.0.(different number) on the laptop
      • Subnet mask default
  • Build program
    • Add Main
    • Simple logic:
      • Normally open input (e.g., I0.0) controlling output (e.g., Q0.0)
    • Optionally name tags for readability
  • Download & test
    • Click Download
    • Choose appropriate interface (mentions “Profet”)
    • Use online view to observe I/Q and validate behavior

E) Training on NO/NC momentary push buttons (field wiring + PLC logic)

  • NO (Normally Open) momentary
    • Normal state: circuit open
    • Press: circuit closes
    • PLC input becomes ON, output turns ON
  • NC (Normally Closed) momentary
    • Normal state: circuit closed
    • Press: circuit opens
    • PLC input becomes OFF, output turns OFF
  • 24 V wiring concept
    • NO button
      • Apply 24 V from PLC power to one side
      • Other side goes to the PLC input channel
    • NC button
      • Similar concept using PLC 24 V, but wired to a PLC input channel such that pressing opens the circuit
  • Common negative / jumper
    • Use M (negative) common via a jumper to multiple inputs
    • Inputs share common negative; only the positive side/channel changes

F) Demonstrating NC behavior and ladder logic differences

  • Using a normally closed contact in ladder logic results in behavior that can be opposite/inverted relative to the raw input hardware state.
  • Two approaches shown:
    • Test actual NO/NC operation using hardware indicators
    • Program with NC/NO contacts to match the intended outcome

G) Latching (seal-in) concept + solving “output drops after momentary press”

  • Problem described
    • Momentary NO push button causes output only briefly (pulse length)
    • Need the output to stay ON after a short press until a stop condition happens
  • Solution
    • Use a feedback (seal-in) path
    • Add a parallel branch where output Q feeds back through a contact (typically using Q0.0 as a normally-open contact) so the circuit stays energized after the input pulse disappears
  • Common real issue during first attempt
    • Improper feedback logic can keep the output ON longer than intended
  • Proper fix
    • Add a STOP button using NC logic
    • STOP is wired/used so that pressing it breaks the latch (turns output OFF)
  • Resulting behavior
    • START (momentary NO) → latches output ON
    • STOP (momentary NC) → unlatches output OFF

Speakers / sources featured

  • Primary speaker/presenter: Unnamed person (multiple segments covering S7-1200 hardware, wiring, TIA Portal programming, and ladder logic)
  • Secondary on-screen host/instructor (separate intro segment): Noman from IT and Automation Academy
  • Brand/source referenced: Siemens (S7-1200, TIA Portal, and the broader Siemens PLC ecosystem)

Rate this summary

Your feedback will help improve summaries.

Improve this summary

Reprocess with a stronger model when the summary feels incomplete or inaccurate.

Pro

Translate summary in another language

Pro

Ask questions to this video

Chat for follow-up questions, clarifications, and source-backed answers.

Coming soon

Share this summary

Original video