Diffraction Lecture 25: Rietveld Refinements

Main summary

Key takeaways

Science and Nature

Scientific concepts, discoveries, and nature/physics phenomena

Inverse crystallography problem (powder vs single crystal)

  • Goal of crystallography: work backward from a diffraction pattern to determine the crystal structure.
  • Single crystals:
    • Peak positions and intensities can be separated more cleanly (via:
      1. indexing
      2. structure factors
      3. phase determination
      4. structural refinement).
  • Powder diffraction:
    • The analysis steps are not cleanly separated because many peaks overlap.
    • Refinement must fit the entire pattern at once.

Diffraction physics in a nutshell

  • Unit cell dimensions determine Bragg peak angles (constructive interference).
  • Structure factors connect peak intensities to the atomic arrangement within the unit cell.
  • Background scattering can include:
    • inelastic scattering (Compton)
    • and other instrumental contributions.

Rietveld method (key discovery)

  • Hugo Rietveld (late 1960s) developed a method for analyzing powder diffraction by fitting the full diffraction pattern simultaneously using a structural model.
  • Motivation: rather than matching individual reflection intensities (difficult due to overlap), fit the pattern globally.

Modeling a powder diffraction pattern (4-part decomposition)

A typical Rietveld-style pattern model can be decomposed into:

  1. Peak positions
    • Determined from lattice parameters (where peaks occur).
  2. Peak intensities / peak areas
    • Related to structure factors (crystallographic information).
  3. Peak profile / peak shape
    • Peaks are not delta functions; width/lineshape matter.
  4. Background
    • Smooth scattering + instrumental and inelastic effects.

Space group assignment and structure solution strategy

  • From powder diffraction, determine:
    • Index peaks → lattice and peak positions
    • Systematic absences → space group
  • Often, instead of a detailed structure factor-based phase solution, use:
    • analogies to similar compounds’ structures
    • estimates based on the number of atoms per unit cell
    • multiplicities of Wyckoff positions
  • Then refine atomic positions using Rietveld refinement.

Peak shape models

  • Common baseline peak shapes:
    • Gaussian
    • Lorentzian (with long tails)
  • Real instruments often produce a mixture:
    • Pseudo-Voigt function with mixing parameter η
      • η = 1 → pure Lorentzian
      • η = 0 → pure Gaussian
  • Peak width variation with diffraction angle:
    • Thompson–Cox–Hastings (TCH) function
    • Uses refinable parameters u, v, w, x, y (as described) to model FWHM vs 2θ
  • Instrumental vs sample broadening
    • Sample effects discussed include:
      • small crystallite size
      • microstrain

Instrument-specific effects on lineshape

Different diffractometers/detectors alter the Gaussian/Lorentzian balance and the peak-width evolution:

  • Point detector vs position-sensitive detector
  • Benchtop (e.g., Cu source) vs synchrotron

Examples described:

  • Benchtop (Rigaku) data: low-angle peaks more Lorentzian; Gaussian component grows with angle.
  • Position-sensitive detector: adds extra Gaussian contribution even at low angles.
  • Synchrotron: extremely sharp peaks at low angles; moderate broadening at higher angles.

Guidelines for collecting powder diffraction data for successful Rietveld refinement

  • Choose geometry/mode
    • Bragg–Brentano (flat plate) vs Debye–Scherrer (capillary transmission).
  • Absorption constraints
    • For capillaries, ensure μR < 1, ideally < 0.1 (otherwise results become unreliable).
    • If absorption is too high:
      • use higher-energy X-rays
      • or dilute the sample.
  • Flat plate considerations
    • Avoid beam spillover (from a divergent slit choice), as it distorts intensities and peak shapes.
    • Preferred orientation (texture) is a known issue for flat plate measurements, breaking the random-orientation assumption.
  • Capillary advantages
    • Reduces preferred orientation issues (when absorption allows).
  • Data coverage and resolution requirements

    • Collect a wide d-spacing range (include high-angle peaks) to reduce overlap and improve weak peak discrimination.
    • Choose a step size small relative to the sharpest peak:
      • typically 5–10× smaller than FWHM (e.g., ~0.01–0.02 for Cu lab data; smaller for synchrotrons).
  • Avoid preprocessing that damages refinements

    • Do not smooth
    • Do not subtract background beforehand
    • Do not remove Kα2 before refinement (these should be modeled during Rietveld refinement).
  • Fluorescence and absorption edges
    • With Cu radiation, elements like Fe and Co can cause strong fluorescence, increasing background and affecting scattering.
    • Certain lanthanides (Cs–Dy) have problematic L-edges with Cu radiation.
    • Some transition elements may also be affected (e.g., 5d-related effects were mentioned).

Methodology / workflow outlined in the subtitles

Powder diffraction + Rietveld refinement workflow (high-level)

  1. Collect powder diffraction pattern
  2. Index peaks to determine lattice/peak positions
  3. Analyze systematic absences to assign a space group
  4. Generate an initial structural model
    • by analogy to related structures, or
    • using number of atoms/unit cell and Wyckoff multiplicities
  5. Refine the structure by fitting the entire pattern
    • refine simultaneously:
      • peak positions
      • peak intensities
      • peak profile/shape
      • background

Pattern decomposition into four modeled components

  • (1) Peak positions
    • lattice-parameter dependent
  • (2) Peak intensities
    • peak area/intensity linked to structure factors
  • (3) Peak profile/shape
    • Gaussian/Lorentzian mixture (Pseudo-Voigt with η)
    • width varying with 2θ (TCH model)
  • (4) Background
    • modeled with few terms (e.g., Chebyshev polynomials)
    • or via interpolation between selected background points

Background modeling guideline

  • Start with few polynomial terms (e.g., ~3–4 rather than many).
  • Add terms only if necessary to avoid:
    • background “wiggling”
    • strong correlation between background parameters and peak intensities.

Researchers / sources featured

  • Dr. Curtis Moore (instructor; previously discussed single crystal methods)
  • Hugo Rietveld (developer of the Rietveld method; described as Dutch crystallographer, late 1960s)
  • Art Slate (PhD supervisor mentioned by the lecturer)
  • Noah Hozapfel (name associated with data refined in the lecturer’s group)
  • Lynn McCusker (author of refinement guidelines paper)
  • Bob von Dreele (author of refinement guidelines paper)
  • Dave Cox (author of refinement guidelines paper)
  • Daniel Luer (author of refinement guidelines paper)
  • Paulo Scardi (author of refinement guidelines paper)
  • Argonne National Laboratory
    • referenced as a source/location mentioned for absorption edge lookup tooling (no individual named)

Rate this summary

Your feedback will help improve summaries.

Improve this summary

Reprocess with a stronger model when the summary feels incomplete or inaccurate.

Pro

Translate summary in another language

Pro

Ask questions to this video

Chat for follow-up questions, clarifications, and source-backed answers.

Coming soon

Share this summary

Original video