- Designing a potable (drinking) water distribution plan for a housing development is presented as the simplest workflow compared with other utility-plan types.
-
The video follows a step-by-step workflow:
- Start from a site plan/layout (lots, green areas, courts, pool/amenities).
- Insert potable water pipe routing in the streets using set spacing/separation rules from other utilities—especially sewer and stormwater.
- Place house service connections, ensuring the correct fitting arrangement and distances.
- Add provisions/branches for community areas (parks, maintenance station, changing rooms, pools, etc.).
- Place hydrants to meet coverage needs without unnecessary extra cost.
- Measure pipe section lengths, assign pipe diameters (with guidance on minimums), and perform water consumption/flow calculations per pipe segment.
- Build a total water consumption table (section-by-section), then compute flow at each segment by subtracting downstream consumption.
- Indicate flow direction with arrows and keep symbology/labeling consistent in the final drawing/table.
Methodology / instructions (detailed)
1) Prepare the base layout
- Use the housing development site design including:
- lots (house plots),
- green areas,
- children’s play areas,
- pools,
- changing rooms,
- courts,
- and other existing features.
- Conceptually treat the plan like a site design, but omit some elements that appear in other utility plan types (the speaker mentions removing numbers/fees and focusing on pipes).
2) Place potable water pipes relative to street utilities
A referenced document provides typical placement rules. The key rules stated are:
-
Orientation concept
- Determine street directions (example used: “north” toward the front).
-
Street center references
- The municipal sewer line is almost always near the center of the street.
- Stormwater runoff lies to the right of this (as described in the example).
-
Horizontal offset from curb
- Potable water pipe runs from the curb toward the street:
- typically 1.5 meters from the curb, or
- at least 1.5 meters when possible.
- Potable water pipe runs from the curb toward the street:
-
Separation from sewer line
- Potable water pipe must be at least 1 meter from the center of the sewer pipe.
-
Vertical separation
- Minimum 20 centimeters vertical separation is required.
- Potable water pipe must be above the sewer pipe.
-
How to depict in plan view
- Based on street types/orientation used in the example:
- On avenues: sewer pipes are above the street; potable lines follow the described offsets.
- On streets: sewer pipes are to the left (above and left relative to the center); potable line positioned using the stated 1.5 m offsets.
- Based on street types/orientation used in the example:
3) Draw each house service connection to the main
-
In the drawing delivery/mechanical plan context:
- Place the pipe route according to the mechanical plan and lot layout.
-
Pipe inlet/service location
- Example given: inlet distance such as 90 centimeters from a reference point along the lot direction.
-
Correct fitting scheme
- The speaker says a previous representation is wrong and must be corrected.
- Use:
- cross connections and appropriate fittings,
- two 90-degree elbows in the described arrangement,
- plugs at corners/ends to allow continuation later if needed.
-
Plug placement guidance
- Instead of only placing plugs at the extreme end of a cross, place plugs at additional corner/end points where appropriate.
-
Drawing quality/line visibility
- For legibility:
- draw the main street pipe with higher-quality emphasis,
- draw smaller internal fittings/connections with thinner/lower visibility so they don’t look overly prominent.
- For legibility:
4) Add provisions for amenities and special areas
- Where there are:
- parks,
- guard booth / maintenance station,
- green spaces and large courts,
- pool/changing-room areas,
- etc.
- Add water provisions/connection points so these amenities can be supplied.
- Examples mentioned:
- one provision for changing rooms,
- one provision for the pool.
- For pools, the speaker notes installations may already include some aspects, but project provisions must still be placed where required.
5) Place hydrants with coverage considerations
- Hydrants are described as covering a radius of about 150 meters (practically along curves).
- Key logic:
- Coverage should be broad enough to cover neighborhoods/street segments.
- Avoid placing only one hydrant in a way that would cause major impact if it fails (repairs/breakdown).
- Hydrants are expensive, so do not overspecify beyond what the layout requires.
-
Placement depends on:
- number of streets,
- how hydrants provide access/coverage to each street.
-
Graphic representation:
- hydrants appear as a valve-like circle (per the schematic style shown).
6) Measure pipe sections and label changes/breakpoints
- Place the main pipe layout on the street using continuous lines (speaker references a “center line” concept).
-
Measure lengths of each pipe “piece” between break points.
- For each section segment, measure and label the distance.
-
Emphasis from the video:
- planned segments aren’t counted in certain total-length assumptions,
- but each break / change of direction matters.
-
Diameter labeling / constraints:
- Reference to 100 millimeters (noted as a minimum in the example).
- Other minimums like 50 and 75 are mentioned; the speaker suggests using 75 or keeping 100 depending on the feeding situation.
- Rationale: hydrants require 100 mm in the example, so the plan may keep 100 mm across sections where hydrant supply drives the design.
7) Compute valve locations for maintainability
- Goal: design so repairs don’t require shutting down all streets/areas.
- Strategy:
- Subdivide the network into sections.
- Install valves near strategic points so sections can be isolated.
- Example approach:
- put valves near the point where you’d isolate for repair (try to keep sections intact).
- multiple valve placements isolate different groups of downstream branches.
- Each valve is assigned a letter.
- The plan should include a total water consumption table referencing:
- total consumption per section,
- section number,
- number of houses / connections per section,
- and flow rate (L/s) per section.
8) Build the “total water consumption” table
8.1 Determine demand per house
- Baseline calculation:
- 200 liters/day per person = 0.0231 liters/second per person.
- multiply by an expansion factor = 2.25 (to account for multiple people using water simultaneously).
- Example per-house flow:
- if a house averages 5 people:
- per-house flow ≈ 0.26 liters/second (as stated).
- if a house averages 5 people:
8.2 Multiply by number of houses/connections per section
- For each section:
- flow (L/s) = (number of houses/connections) × 0.26
- Add section flows to form totals as needed.
- Spreadsheet caution:
- watch decimal formatting (period vs zero and unit consistency),
- keep numeric/text formatting consistent so decimals don’t become incorrect values.
8.3 Assign which houses belong to which section
- The table includes “planned connections” (houses + special planned connections such as booths).
- Section boundaries may start/end at certain valves and include houses along the route.
- If a region is split, split house counts accordingly.
9) Compute flow along the pipe segments (segment-by-segment subtraction)
- Start with the total inlet flow into the system (example inlet value: 1.27 L/s).
-
Then, move outward segment-by-segment:
- subtract the consumption demand of downstream houses/branches.
-
Flow rule:
- if multiple branches exist, compute downstream segment flows by subtracting what they consume.
- use arrows to define direction of flow.
-
Order of subtraction (procedural detail):
- “Go in this order”:
- subtract downstream demand from horizontal top branches first,
- then horizontal lower branches,
- then additional branches coming down in sequence,
- repeat systematically.
- “Go in this order”:
-
Practical note:
- if a downstream segment has no additional consumers, then that segment’s flow stays the same (no subtraction).
10) Final drawing/table output requirements
Include:
- the consumption table and section/flow values,
- symbology and lettering consistent with a template.
Additional formatting guidance from the speaker:
- consider copying/pasting a prepared table/attachment,
- keep text in stable size so the document doesn’t resize unexpectedly,
- ensure:
- lettering height is consistent (example mentioned: 2.5),
- segment flow values use consistent decimal places (speaker mentions placing a fixed number of decimals in one example to maintain consistency).
Also include:
- arrow(s) indicating flow direction (explicitly for showing where water goes, not necessarily slope direction).