Key takeaways
Main ideas and lessons
1) Lecture purpose and learning outcomes
- The lecture is part of an architectural design “course achievement” (CPMK/DU) focused on the ability to create architectural design ideas using basic design methods.
- Today’s focus is the utilities of a simple one-floor building, especially:
- Sanitation/Water systems (clean water + dirty water)
- Drainage
- Electric basics (lighting and related components)
- Learning flow mentioned:
- Understand what utilities are
- Study examples for:
- Clean water sanitation systems
- Dirty water sanitation systems
- Drainage systems
- Basic electricity (e.g., light point)
2) Core concept: “Utility” in architecture
- Utilities are framed as essential to ensure architecture supports:
- Comfort, health, safety, communication, and mobility
- Utilities are described as the building equipment/facilities that complete a building so it is:
- Practical, useful, and functions properly both inside and outside.
- Why utilities must be studied/planned:
- Different building types (house vs hospital vs office) have different utility requirements
- Planning utilities helps minimize waste and mistakes in installation networks (piping, electrical, etc.)
- Improves safety, comfort, and usability
- Makes future repairs easier via the availability of installation drawings (network layouts/plans)
3) Basic utility systems in a simple building (one-floor scheme)
- The lecture provides a “simple building utilities” overview consisting of:
- Electricity
- Includes lighting
- Mentions HVAC (heating, ventilation, air conditioning) as later complexity
- Water
- Clean water system
- Dirty water system
- Drainage system
- Electricity
- Additional supporting systems briefly mentioned:
- Lightning protection
- Security system/locks
- Internet/telephone system
4) Sanitation: definitions and water sources (clean vs dirty)
A. Sanitation definition
- Sanitation is presented as a health effort to maintain and protect the environment from harmful impacts.
B. Clean water sources
Clean water can come from:
- Wells/groundwater
- Water tanks/reservoirs
- PDAM (government/local government managed water supply)
- PAM (private sector managed water supply)
C. Dirty water categories
Dirty water includes:
- Rainwater
- Drainage
- Wastewater, divided into:
- Black water: urine and feces
- Grey water: liquid waste with fats (e.g., dishwashing, laundry)
D. Ending point of wastewater
- Grey/black waste is directed toward systems like:
- Septic tank
- Absorption/soakage well (infiltration)
- Overflow/excess can be channeled onward to sewer/other channels
Methodology / step-by-step instructions (planning utilities)
A) Determining clean water requirement (simple assumptions)
- Assume ~150 liters per person per day
- Steps:
- Estimate number of residents
- Multiply daily need by occupants
- Adjust according to activities (examples):
- Kitchen needs: washing, cooking, rinsing
- Garden watering
- Bathroom needs
- Clothes washing
B) Choosing and understanding clean water distribution systems
Two main clean-water distribution methods are described:
-
Downfeed (downfit / top reservoir gravity system)
- Source water is collected in a lower tank, then pumped up.
- From the upper reservoir, water is distributed downward to rooms.
- Advantages:
- Pump doesn’t run continuously (uses gravity)
- Reservoir above provides water availability
- Drawbacks:
- Requires a tank on top
- Adds cost, structural load, and maintenance effort
-
Upfeed (upfit / direct upward pressure system)
- Water is distributed from bottom to top directly when needed.
- Requires a booster/push pump.
- Advantages:
- Often more practical for small houses/buildings
- Drawbacks:
- Pump runs when taps are opened
- Height/pressure limitations (pump pressure decreases over distance)
C) Clean-water planning notes (wells, pumps, connections)
- Reservoir positioning:
- Place tank at least at/above roof height to support gravity distribution
- Pumps:
- Should not be directly exposed to water (not water/dust resistant)
- Rain exposure risk: pump housing durability is a concern
- Connection types for supplied water:
- Direct connection from public supply pipes:
- Provides a meter/control box and then feeds taps
- Meter location considerations (public water infrastructure constraints)
- Combined well + public supply:
- Multiple sources feed into a shared controlled system (valves regulate each source)
- Direct connection from public supply pipes:
Dirty water + drainage planning requirements (key rules)
A) Separation and safe distances (clean well vs septic)
- Minimum distance between:
- Clean water well and septic tank: 10–15 meters
- Rationale:
- Prevent contamination and protect water sanitation/health.
B) Plumbing/delivery rules for dirty water networks
- Dirty water (untreated) should not go directly into public drainage.
- Steps for disposal flow:
- Route dirty water into septic tank first
- Then discharge to seepage/absorption area
- Remaining water is filtered before reaching city sewer/related channels
- Chemical warning:
- Do not throw chemicals into septic/BC system (can damage bacteria needed for treatment)
- Channel design rules:
- Use the shortest practical route, but ensure correct engineering
- Keep pipes as high as possible/avoid placing deep under buildings
- If under floor and damaged, repairs require dismantling
- Provide control tanks, especially at:
- Each connection or bend
- Areas where people pass (inside/outside both mentioned)
- Minimum vertical slope of channels: ~2%
- Maximum diversion angle when changing direction: ~45°
- Protect connections between tanks
C) Black water system (toilet/septic system)
- Basic routing:
- Toilet waste → direct to septic tank (ideally minimal detours)
- Septic tank functions:
- Solid waste settles/precipitates
- Liquid portion flows onward after treatment
- Key safety requirement:
- Septic tanks must include an air vent/ventilation hole to release methane gases
- Without ventilation: risk of gas saturation and possible explosion
- Materials:
- Septic tanks may be concrete, fiberglass, plastic, etc.
- Bio-septic tanks also mentioned as a variation
D) Grey water system (soapy/fat-containing waste)
- Grey water characteristics:
- Comes from soap waste (laundry/dishes)
- Concentration is stated as lower than black water
- Routing described:
- Goes to a control tank (to check blockage/condition)
- Then directed to soakage/infiltration or absorption well
- Grease trap concept:
- For soapy/fatty waste, a fat/grease catching tank is recommended
- Grease trap can be installed inside or outside, depending on design
E) Rainwater drainage / disposal system
- Rainwater can be channeled directly into surrounding gutters because it is relatively “clean water + dirt.”
- Recommended form:
- Open channels are suggested
- Alternative:
- Collect rainwater into rainwater infiltration wells
- Separation principle:
- Do not mix rainwater infiltration with dirty water absorption wells
- Goal: rainwater can be reused (examples mentioned: watering plants, washing hands)
F) Infiltration enhancement
- Use biopore holes:
- Increase infiltration
- Support organic composting in the soil
- Create small tunnels improving soil fertility
Output deliverables / tasks assigned
- Create a sanitation plan drawing including:
- Clean water system
- Dirty water system
- Drainage system
- Create a lighting point plan based on the design created.
Notes on ceiling + lighting basics (electric utility portion)
Ceiling functions
A ceiling is described as providing:
- Aesthetics for the room
- Limits room height
- Heat insulation
- Soundproofing
- Space to hang lights and support installations
Ceiling types (introduced)
- Drop ceiling (lowered from original ceiling plane)
- Curved ceiling / shaped ceilings (including rhythmic curves)
- Tiered/stepped
- Ceiling with niches / recessed forms
- If no ceiling (roof exposed directly):
- Still may use lighting arrangement directly under the roof plane
Lighting plans and electrical notation
- Lighting is designed using:
- Ceiling plan and electrical point layout
- Lighting system details noted:
- Ceiling plan is often separate from electrical drawing
- Electrical point plan may also include fans/AC/exhaust fans
- Switch and circuit mapping concept:
- Example method described:
- Label switches (A, B, C)
- Label lights (A1–A4, B1–B4, etc.)
- Indicate which switch controls which light group
- Emphasis:
- Notation must be consistent and should include cable depiction (not only dots)
- Example method described:
References and standards mentioned
- Standard books mentioned:
- Hafreak (title referenced as construction science of building equipment/utilities)
- Additional supporting references:
- SNI (Indonesian national standards)
- Technical standard example referenced:
- Procedures/standards for septic tank planning
- Distances aligned with SNI (exact values mentioned include 10–15 m, among other ranges discussed)
Speakers / sources featured
- Marcus Vitruvius Pollio (Vitruvius) — credited with the utility concept and quoted architectural principles (comfort, beauty, utility).
- FITROVIUS — referenced as “Vitruvius” (appears to be the same source).
- Hefreak — referenced as an author/source of a construction/utility textbook.
- SNI (Indonesian National Standards) — cited as the standard reference for technical requirements (e.g., septic planning, distances).